1 - 11 |
Predicting future monthly residential energy consumption using building characteristics and climate data: A statistical learning approach Williams KT, Gomez JD |
12 - 21 |
Experimental study of an active slab with PCM coupled to a solar air collector for heating purposes Navarro L, de Gracia A, Castell A, Cabeza LF |
22 - 37 |
Review and recent improvements of solar sorption cooling systems Bataineh K, Taamneh Y |
38 - 55 |
Comparison of prediction models for determining energy demand in the residential sector of a country Soto AM, Jentsch MF |
56 - 67 |
The effect of time-of-use tariffs on the demand response flexibility of an all-electric smart-grid-ready dwelling Pallonetto F, Oxizidis S, Milano F, Finn D |
68 - 80 |
Empirical evaluation of the energy and environmental performance of a sustainably-designed but under-utilised institutional building in the UK Gupta R, Gregg M |
81 - 98 |
Development of Matlab-TRNSYS co-simulator for applying predictive strategy planning models on residential house HVAC system Alibabaei N, Fung AS, Raahemifar K |
99 - 110 |
A comprehensive review on design of building integrated photovoltaic system Shukla AK, Sudhakar K, Baredar P |
111 - 118 |
Thermal assessment of ambient pressure dried silica aerogel composite boards at laboratory and field scale Martinez RG, Goiti E, Reichenauer G, Zhao SY, Koebel M, Barrio A |
119 - 131 |
Probabilistic behavioural modeling in building performance simulation-The Brescia eLUX lab Tagliabue LC, Manfren M, Ciribini ALC, De Angelis E |
132 - 142 |
Collaborating in decision making of sustainable building design: An experimental study comparing CBA and WRC methods Arroyo P, Fuenzalida C, Albert A, Hallowell MR |
143 - 154 |
Performance evaluation of conventional demand response at building-group-level under different electricity pricings Shen LM, Li ZW, Sun YJ |
155 - 163 |
Thermal perception and skin temperature in different transient thermal environments in summer Xiong J, Zhou X, Lian ZW, You JX, Lin YB |
164 - 177 |
Application of dynamic analysis and modelling of structural concrete insulated panels (SCIP) for energy efficient buildings in seismic prone areas Bhatti AQ |
178 - 189 |
Lifecycle costing of low energy housing refurbishment: A case study of a 7 year retrofit in Chester Road, London Neroutsou TI, Croxford B |
190 - 197 |
The effects of urban microclimate on outdoor thermal sensation and neutral temperature in hot-summer and cold-winter climate Liu WW, Zhang YX, Deng QH |
198 - 213 |
Building energy-consumption status worldwide and the state-of-the-art technologies for zero-energy buildings during the past decade Cao XD, Dai XL, Liu JJ |
214 - 223 |
Integrating building performance simulation in agent-based modeling using regression surrogate models: A novel human-in-the-loop energy modeling approach Papadopoulos S, Azar E |
224 - 235 |
An evaluation of HVAC energy usage and occupant comfort in religious facilities Terrill TJ, Rasmussen BP |
236 - 253 |
An approach to modelling envelope airtightness in multi-family social housing in Mediterranean Europe based on the situation in Spain Fernandez-Aguera J, Dominguez-Amarillo S, Sendra JJ, Suarez R |
254 - 261 |
Performance evaluation and life cycle analysis of earth to air heat exchanger in a developing country Uddin MS, Ahmed R, Rahman M |
262 - 269 |
Effective use of a ground-source heat-pump system in traditional Japanese "Kyo-machiya" residences during winter Hagihara K, Iba C, Hokoi S |
270 - 286 |
Decision-making process for improving thermal and energy performance of residential buildings: A case study of constructive systems in Brazil Silva AS, Almeida LSS, Ghisi E |
287 - 304 |
Energy use and carbon reduction potentials from residential ground source heat pumps considering spatial and economic barriers Lim TH, De Kleine RD, Keoleian GA |
305 - 318 |
Visual comfort assessment of daylit and sunlit areas: A longitudinal field survey in classrooms in Kashan, Iran Korsavi SS, Zomorodian ZS, Tahsildoost M |
319 - 335 |
Advances in building simulation and computational techniques: A review between 1987 and 2014 Wang HD, Zhai Z |
336 - 348 |
Laboratory measurement of thermal distribution throughout the insulation materials using the Peltier module while managing elimination of external influences Antonyova A, Antony P, Korjenic A |
349 - 359 |
Degree of freedom based set-point reset scheme for HVAC real-time optimization Asad HS, Yuen RKK, Huang GS |
360 - 369 |
Energy saving potential of a novel phase change material wallboard in typical climate regions of China Zhu N, Liu FL, Liu PP, Hu PF, Wu MD |
370 - 383 |
Impact of a grid-connected PV system application in a bioclimatic house toward the zero energy status in the north of Algeria Missoum M, Hamidat A, Imessad K, Bensalem S, Khoudja A |
384 - 393 |
Evaluation of the potential energy recovery for ventilation air in dwellings in the South of Europe Guillen-Lambea S, Rodriguez-Soria B, Marin JM |
394 - 404 |
Life-time performance of post-disaster temporary housing: A case study in Nanjing Song YM, Mithraratne N, Zhang H |
405 - 412 |
Estimating the impact of reveals on the transmission heat transfer coefficient of internally insulated solid wall dwellings Marincioni V, Altamirano-Medina H, May N, Sanders C |
413 - 430 |
Energy analysis of the daylighting from a double-pane glazed window with enclosed horizontal slats in the tropics Fathoni AM, Chaiwiwatworakul P, Mettanant V |
431 - 441 |
Applications of machine learning methods to identifying and predicting building retrofit opportunities Marasco DE, Kontokosta CE |
442 - 457 |
Cost-effective analysis for selecting energy efficiency measures for refurbishment of residential buildings in Catalonia Ortiz J, Casas AFI, Salom J, Soriano NG, Casas PFI |
458 - 472 |
Effects of added glazing on Balcony indoor temperatures: Field measurements Hilliaho K, Kolio A, Pakkala T, Landensivu J, Vinha J |
473 - 483 |
Automated control calibration exploiting exogenous environment energy: An Israeli commercial building case study Michailidis IT, Korkas C, Kosmatopoulos EB, Nassie E |
484 - 490 |
Cost-benefit evaluation for building intelligent systems with special consideration on intangible benefits and energy consumption Chen ZL, Wang FL, Feng QQ |
491 - 502 |
Laboratory investigations of the thermal performance of an energy pile with spiral coil ground heat exchanger Yang WB, Lu PF, Chen YP |
503 - 510 |
Constant design air flow industrial ventilation systems with regenerative dust filters: Economic comparison of fan speed-controlled, air damper controlled and uncontrolled operation Lanzerstorfer C, Neder F, Schmied R |
511 - 518 |
Comparison of the overall energy performance of semi-transparent photovoltaic windows and common energy-efficient windows in Hong Kong Zhang WL, Lu L, Peng JQ, Song AT |
519 - 529 |
A data-driven strategy for detection and diagnosis of building chiller faults using linear discriminant analysis Li D, Hu GQ, Spanos CJ |
530 - 539 |
Analysis of real-time electricity consumption in Canadian school buildings Ouf M, Issa M, Merkel P |
540 - 552 |
Assessing the energy intensity of peri-urbanisation: A master plan approach Gauk M, Roose A |
553 - 566 |
A branch and bound approach for building cooling supply control with hybrid model predictive control Mayer B, Killian M, Kozek M |
567 - 574 |
Experimental assessment on a kind of composite wall incorporated with shape-stabilized phase change materials (SSPCMs) Wang X, Yu H, Li L, Zhao M |
575 - 582 |
Recovering heat from hot drain water-Experimental evaluation, parametric analysis and new calculation procedure Ramadan M, Lemenand T, Khaled M |
583 - 591 |
The influence of seasonal characteristics in elderly thermal comfort in Korea Yang J, Nam I, Sohn JR |
592 - 604 |
An integrated BIM-based framework for minimizing embodied energy during building design Shadram F, Johansson TD, Lu WZ, Schade J, Olofsson T |
605 - 616 |
Prediction of surface temperatures for the assessment of urban heat island effect over Ahmedabad city using linear time series model Mathew A, Sreekumar S, Khandelwal S, Kaul N, Kumar R |
617 - 638 |
Cooling the buildings - past, present and future Santamouris M |
639 - 648 |
Analysing wastewater temperature development in a sewer system as a basis for the evaluation of wastewater heat recovery potentials Kretschmer F, Simperler L, Ertl T |
649 - 659 |
Energy and economic analysis and feasibility of retrofit actions in Italian residential historical buildings Ciulla G, Galatioto A, Ricciu R |
660 - 672 |
Method for obtaining reference buildings Schaefer A, Ghisi E |
673 - 685 |
Life cycle assessment of shipping container home: A sustainable construction Islam H, Zhang GM, Setunge S, Bhuiyan MA |
686 - 696 |
Experimental comparison between set-point based and satisfaction based indoor thermal environment control Wang FL, Chen ZL, Feng QQ, Zhao QC, Cheng ZJ, Guo Z, Zhong ZP |
697 - 712 |
Climate-responsive design of traditional dwellings in the cold-arid regions of Tibet and a field investigation of indoor environments in winter Huang LJ, Hamza N, Lan B, Zahi D |
713 - 722 |
Cooperative optimization of building energy systems in an economic model predictive control framework Staino A, Nagpal H, Basu B |
723 - 733 |
Impact of PV and variable prices on optimal system sizing for heat pumps and thermal storage Fischer D, Lindberg KB, Madani H, Wittwer C |
734 - 755 |
Evaluating energy performance in non-domestic buildings: A review Borgstein EH, Lamberts R, Hensen JLM |
756 - 771 |
Increasing homeowners' insulation activity in Germany: An empirically grounded agent-based model analysis Friege J |
772 - 784 |
Economic assessments of passive thermal rehabilitations of dwellings in Mediterranean climate Santamaria J, Giron S, Campano MA |
785 - 797 |
Thermo - lighting optimization proposal for school buildings in subtropical hot - humid climates: Monitoring and computer simulation on autumn period Boutet ML, Hernandez AL, Jacob GJ |
798 - 808 |
Dynamic coupling between a Kriging-based daylight model and building energy model Yi YK |
809 - 818 |
Applying relative equivalent uniform annual benefit for optimum selection of a gas engine combined cooling, heating and power system for residential buildings Sanaye S, Ghafurian MM |
819 - 826 |
System analysis and appraisal of SOFC-primed micro cogeneration for residential application in subtropical region Fong KF, Lee CK |
827 - 833 |
A novel methodology for determining sky blocking by obstacles viewed virtually from any location on site Rehman NU, Siddiqui MA |
834 - 844 |
Ventilation guidelines for controlling smoke, dust, droplets and waste heat: Four representative case studies in Chinese industrial buildings Huang YQ, Wang Y, Ren XF, Yang Y, Gao J, Zou Y |
845 - 866 |
Natural convection subject to sinusoidal thermal forcing on inclined walls and heat source located on bottom wall of an attic-shaped space Sojoudi A, Saha SC, Sefidan AM, Gu YT |
867 - 875 |
Numerical simulation of particle deposition in duct air flows with uniform, expanding or contracting cross-section Lu H, Lu L, Jiang Y |
876 - 885 |
Exergy and entransy analyses in air-conditioning system part 1-Similarity and distinction Zhang T, Liu XH, Tang HD, Liu J, Jiang Y |
886 - 899 |
Evaluation of energy conservation opportunities through Energy Performance Contracting: A case study in Italy Principi P, Fioretti R, Carbonari A, Lemma M |
900 - 910 |
Analysis and evaluation of a new renewable energy based integrated system for residential applications Panchal S, Dincer I, Agelin-Chaab M |
911 - 920 |
Greenhouse gas mitigation benefits and cost-effectiveness of weatherization treatments for low-income, American, urban housing stocks Bradshaw JL, Bou-Zeid E, Harris RH |