1 - 9 |
Balance point temperature for heating as a function of glazing orientation and room time constant Verbai Z, Csaky I, Kalmar F |
10 - 19 |
The effect of living wall systems on the thermal resistance of the facade Tudiwer D, Korjenic A |
20 - 32 |
Infrared thermography technique as an in-situ method of assessing heat loss through thermal bridging O'Grady M, Lechowska AA, Harte AM |
33 - 38 |
Y Energy performance of a medium scale green roof system installed on a commercial building using numerical and experimental data recorded during the cold period of the year Foustalieraki M, Assimakopoulos MN, Santamouris M, Pangalou H |
39 - 49 |
A rapid evaluation method of existing building applied photovoltaic (BAPV) potential Zhang W, Zhang YK, Li Z, Zheng Z, Zhang R, Chen JX |
50 - 61 |
Analysis of the performance of a tankless water heating combo system: Simultaneous space heating and domestic hot water operation Der JP, Kostiuk LW, McDonald AG |
62 - 73 |
Development and validation of an intelligent load control algorithm Kim W, Katipamula S |
74 - 84 |
Y Coupled heat and moisture transfer in hollow concrete block wall filled with compressed straw bricks Hou SD, Liu FS, Wang SJ, Bian HB |
85 - 94 |
A comparative embodied energy analysis of a house with recycled expanded polystyrene (EPS) based foam concrete wall panels Dissanayake DMKW, Jayasinghe C, Jayasinghe MTR |
95 - 108 |
Energy transfer and energy saving potentials of air-to-air membrane energy exchanger for ventilation in cold climates Liu P, Alonso MJ, Mathisen HM, Simonson C |
109 - 118 |
Modelling and experimental determination of thermal properties of local wet building materials Damfeu JC, Meukam P, Jannot Y, Wati E |
119 - 127 |
Reducing energy use for water supply to China's high-rises Smith K, Liu SM, Liu Y, Liu Y, Wu YP |
128 - 136 |
Numerical and experimental study of a novel compact micro fluidized beds reactor for CO2 capture in HVAC Li XF, Wang L, Jia L, Cai WJ |
137 - 147 |
Testing the accuracy of low-cost data streams for determining single-person office occupancy and their use for energy reduction of building services Newsham GR, Xue H, Arsenault C, Valdes JJ, Burns GJ, Scarlett E, Kruithof SG, Shen WM |
148 - 155 |
A context-awareness system that uses a thermographic camera to monitor energy waste in buildings Lee C, Yang H |
156 - 165 |
Development of an automatic calibration method of a VRF energy model for the design of energy efficient buildings Yun GY, Song K |
166 - 175 |
Characterizing variations in variable air volume system controls Pang XF, Piette MA, Zhou N |
176 - 186 |
Building thermal design for solar photovoltaic air-conditioning in Australian climates Goldsworthy MJ |
187 - 200 |
Influence of internal heat sources on thermal resistance evaluation through the heat flow meter method Guattari C, Evangelisti L, Gori P, Asdrubali F |
201 - 211 |
Assessing the impacts of real-time occupancy state transitions on building heating/cooling loads Yang Z, Becerik-Gerber B |
212 - 224 |
Improving transient thermal simulations of single dwellings using interpolated weather data Oller PE, Rodriguez JMA, Gonzalez AS, Farina EA, Alvarez EG |
225 - 232 |
Prediction method of real discount rate to improve accuracy of life-cycle cost analysis Lee C, Lee EB |
233 - 243 |
Experimental study on the thermal performance of an enhanced-convection overhead radiant floor heating system Wang DJ, Wu CJ, Liu YF, Chen PH, Liu JP |
244 - 252 |
Statistically informed static pressure control in multiple-zone VAV systems Tukur A, Hallinan KP |
253 - 262 |
Heat source discrimination in buildings to reconstruct internal gains from temperature measurements Brouns J, Nassiopoulos A, Limam K, Bourquin F |
263 - 285 |
Temperature and humidity adaptive control in multi-enclosed thermal zones under unexpected external disturbances Buonomano A, Montanaro U, Palombo A, Santini S |
286 - 301 |
Life cycle assessment (LCA) of building refurbishment: A literature review Vilches A, Garcia-Martinez A, Sanchez-Montanes B |
302 - 311 |
The effect of dynamic solar shading on energy, daylighting and thermal comfort in a nearly zero-energy loft room in Rome and Copenhagen Skarning GCJ, Hviid CA, Svendsen S |
312 - 323 |
A field study of thermal comfort performance for a slotted louvre ventilation system in a low energy retrofit O'Donovan A, O'Sullivan PD, Murphy MD |
324 - 337 |
Will cool roofs improve the thermal performance of our built environment? A study assessing roof systems in Bahrain Radhi H, Sharpies S, Taleb H, Fahmy M |
338 - 349 |
A multistage stochastic energy model with endogenous probabilities and a rolling horizon Champion BR, Gabriel SA |
350 - 366 |
A generalised model of electrical energy demand from small household appliances Sancho-Tomas A, Sumner M, Robinson D |
367 - 384 |
Energy and indoor environmental performance of typical Egyptian offices: Survey, baseline model and uncertainties Elharidi AM, Tuohy PG, Teamah MA, Hanafy AA |
385 - 397 |
Application of the malfunction thermoeconomic diagnosis to a dynamic heating and DHW facility for fault detection Picallo-Perez A, Sala-Lizarraga JM, Iribar-Solabarrieta E, Odriozola-Maritorena M, Portillo-Valdes L |
398 - 409 |
Inferring the thermal resistance and effective thermal mass distribution of a wall from in situ measurements to characterise heat transfer at both the interior and exterior surfaces Gori V, Marincioni V, Biddulph P, Elwell CA |