화학공학소재연구정보센터

Heat Transfer Engineering

Heat Transfer Engineering, Vol.38, No.11-12 Entire volume, number list
ISSN: 0145-7632 (Print) 

In this Issue (16 articles)

987 - 989 Selected Papers From the 17th IAHR (International Association for Hydro-Environment Engineering and Research) International Conference on Cooling Tower and Heat Exchanger
Hooman K, Guan ZQ, Gurgenci H
990 - 999 Comparison of a Basic Organic Rankine Cycle and a Parallel Double-Evaporator Organic Rankine Cycle
Dai YP, Hu DS, Wu Y, Gao YK, Cao Y
1000 - 1007 Efficiency of a Combined Desalination and Power System Utilizing a Two-Phase Flow Multistream Heat Exchanger
Araghi AH, Khiadani M, Hooman K, Lucas G
1008 - 1017 A Novel Experimental Method to Assess Particle Deposition in Idealized Porous Channels
Kuruneru STW, Sauret E, Saha SC, Gu YT
1018 - 1033 Design Sensitivity Analysis of a Plate-Finned Air-Cooled Condenser for Low-Temperature Organic Rankine Cycles
Kaya A, Lazova M, Bagci O, Lecompte S, Ameel B, De Paepe M
1034 - 1043 Water Consumption Comparison Between a Natural Draft Wet Cooling Tower and a Natural Draft Hybrid Cooling TowerAn Annual Simulation for Luoyang Conditions
Xia L, Li JS, Ma W, Gurgenci H, Guan ZQ, Wang P
1044 - 1053 Performance Evaluation and Design of a New Cooling Tower Spray System for Uniform Water Distribution
Roux D, Reuter HCR
1054 - 1062 Numerical Study on the Performance of a Natural Draft Cooling Tower With Water-Cooled Collectors
Zhao SA, Song XJ, Guo FM, Feng J, Zhang DW
1063 - 1072 CFD Modeling of Legionella's Atmospheric Dispersion in the Explosive Outbreak in Murcia, Spain
Consuegro AJ, Kaiser AS, Zamora B, Viedma A, Sanchez F, Hernandez M, Lucas M, Ruiz J
1073 - 1088 An Investigation on Cooling Performance of Air-Cooled Heat Exchangers Used in Coal Seam Gas Production
Lu YS, Guan ZQ, Hooman K, Parulekar PS
1089 - 1100 Enhancing Turbine Output at Dry-Cooled Power Plants Using a Hybrid (Dry/Wet) Dephlegmator
Owen M, Kroger D, Reuter H
1101 - 1107 Investigation of Natural Draft Cooling Tower in China
Li WQ, Chai JY, Zheng JW
1108 - 1116 Effect of Cross Wind on Performances of Natural Draft Counterflow Cooling Tower Outlet
Zhao SA, Wang MR, Li LJ, Du CQ
1117 - 1126 Numerical Simulation of Influence of Arrangement of Flue Gas Discharge Devices on Performances of Indirect Dry Air Cooling Tower
Li LJ, Zhao SA, Song XJ
1127 - 1134 Behavior of Reinforced Concrete Cooling Tower Shell under Lateral Load on Nonuniform Foundation
Hara T
1135 - 1145 Multi-Objective Optimization Analysis of Structural Design for Large Cooling Towers
Zhao L, Chen X, Liang YW, Ge YJ, Sun W, Li YN, Huang SK, He JT, Li YT