화학공학소재연구정보센터
IEEE Transactions on Energy Conversion, Vol.22, No.3, 746-754, 2007
Comparison and identification of static electrical terminal fuel cell models
Six steady-state fuel cell electrical terminal models are compared using experimental data from an Avista Laboratories SR-12 500 W proton exchange membrane (PEM) fuel cell. The paper begins by reviewing the physical effects in a fuel cell. The proposed electrical terminal models are introduced in terms of these physical effects, parameterized for identification and compared using the measured data.