Inzynieria Chemiczna i Procesowa, Vol.22, No.3C, 651-656, 2001
Studies of mixing time in an agitated vessel with eccentric impeller
The effect of the eccentricity e/R of the impeller shaft on the mixing time t(m) of the Newtonian liquid agitated by means of the propeller in the vessel of inner diameter D = 0.7 m was studied. The measurements proved that mixing times are comparable in the agitated vessels, for which e/R = 0.43 - 0.57, J = 0 and e/R = 0, J = 4.