Inzynieria Chemiczna i Procesowa, Vol.25, No.3, 1461-1466, 2004
The flow fluctuation characteristics for a non-Newtonian fluid in an SMX static mixer
LDA measurements of the axial velocity of non-Newtonian fluid (CMC) flow at the inlet to and inside the SMX static mixer were presented. The experimental results were evaluated by means of the Fast Fourier Transform (FFT) and resulted in determining the critical Reynolds numbers.