화학공학소재연구정보센터
Journal of Applied Electrochemistry, Vol.28, No.7, 663-672, 1998
A printed circuit board approach to measuring current distribution in a fuel cell
A new method of measuring current distribution in a polymer electrolyte fuel cell of active area 100 cm(2) has been demonstrated, using a printed circuit board (PCB) technology to segment the current collector and flow field. The PCB technique was demonstrated to be an effective approach to fabricating a segmented electrode and provide a useful tool for analysing cell performance at different reactant gas flow rates and humidification strategies. In this initial chapter of work with the segmented cell, we describe measured effects on current distribution of cathode and anode gas stream humidification levels in a hydrogen/air cell, utilizing a Nafion(TM) 117 membrane and single serpentine channel flow fields, and operating at relatively high gas flow rates. Effects of the stoichiometric Bow of air are also shown. A clear trend is seen, apparently typical for a thick ionomeric membrane, of lowering in membrane resistance down the flow channel, bringing about the highest local current density near the air outlet. This trend is reversed at low stoichiometric hows of air. At an air flow rate less than three times stoichiometry, the local performance starts to drop significantly from inlet to outlet, as local oxygen concentration drop overshadows the lowering in resistance along the direction of flow.