화학공학소재연구정보센터
Journal of Energy Engineering-ASCE, Vol.130, No.2, 45-53, 2004
Experimental determination of energy content of unknown organics in municipal wastewater streams
A bomb calorimetry method has been used for the first time to measure the energy content of raw municipal wastewater. The method was first validated using standard compounds (arginine, glucose, and propionic acid) and then tested with municipal sludge samples, with the results compared to previously published values. By drying a large enough sample to yield approximately 0.5 g of solid residue and using benzoic acid in a 1:1 ratio as a combustion aid, an accurate and precise measurement of the energy content of raw municipal wastewater can be made. The energy content measurements indicate that for the full-scale treatment facility examined, the potential energy available in the raw wastewater exceeds the electricity requirements of the treatment process by a factor of 9.3.