Przemysl Chemiczny, Vol.86, No.5, 382-385, 2007
Thermoporometry of macroporous sulfonic cation exchangers
Thermoporometry was used for detg. the pore structure in macroporous sulfonic cation exchangers in the swollen state. A procedure based on differential scanning calorimetly and thermogravimetric anal. was used for studying the water crystal size distribution inside the pores. Log-normal distribution was suggested to describe crystal and pore size distributions.