화학공학소재연구정보센터
Journal of Chemical and Engineering Data, Vol.40, No.2, 468-471, 1995
Vapor-Liquid-Equilibria for the Ethyl Methyl Ketone Plus Water-System with Limited Miscibility
Vapor-liquid equilibrium data were determined for the system ethyl methyl ketone + water at 101.3 kPa with a modified ebulliometer and a flow type dew-point meter. The liquid-liquid equilibrium at the normal boiling temperature was determined by a laser scattering technique. The thermodynamic consistency of the experimental results was tested by a rigorous method.