Journal of Chemical and Engineering Data, Vol.44, No.1, 161-164, 1999
Measurement and correlation of excess molar enthalpies of CO2+CH3OH system in the vicinity of critical point of carbon dioxide
The excess molar enthalpies of the carbon dioxide + methanol system were measured in the vicinity of the critical point of carbon dioxide using a flow-type isothermal microcalorimeter at temperatures 303.15 K and 308.15 K and pressures from 6.5 to 8.0 MPa. A strong dependence of H-E On pressure at this area was observed. The correlation of the excess molar enthalpies was made using a composition-dependent equation composed of two polynomial expressions. It worked successfully for the H-E-x curves including the region where there is a complicated change.
Keywords:HIGH-PRESSURES;TEMPERATURES 298.15;BINARY-MIXTURES;FLUIDMIXTURES;METHANOL;ETHANOL;PLUS;(CARBON-DIOXIDE;EQUILIBRIA;MPA