화학공학소재연구정보센터
Chemical Engineering and Processing, Vol.78, 11-16, 2014
Optimization of flocculation conditions for the separation of TiO2 particles in coagulation-photocatalysis hybrid water treatment
TiO2 mediated photocatalysis can decompose organic micropollutants (e.g., 1.4-dioxane) in water, but the removal of used TiO2 particles is challenging. Although retrofitting enhances the particle separation efficiency, optimizing a coagulation/flocculation process should be most suitable for existing treatment plants. Therefore, the present study investigated the separation characteristics of TiO2 particles added to drinking water treatment processes along with a polyaluminum coagulant. TiO2 photocatalysts were able to achieve significant degradation of 1,4-dioxane (similar to 100% within 50 min) as well as dissolved organic matter (similar to 75% within 150 min) at a TiO2 dose of 1.0 g/L under UV irradiation. Although the TiO2 particle separation efficiency was sensitive to G values, maximal removal occurred at a G value of < 34s(-1) with a coagulant concentration of > 8 mg/L as Al2O3. Sand filters had the capability to remove residual turbid materials and thus, the turbidity of the final product water dropped to as low as 0.1 NTU when the coagulation/flocculation process was preceded. The final effluent quality was comparable to that of a 0.45-mu m membrane filter. The post separation of the TiO2 photocatalysts dispersed for emergency water treatment to degrade 1,4-dixoane was successfully achieved with an optimal coagulant dose, proper flocculation, and sand filtration. (C) 2014 Elsevier B.V. All rights reserved.