화학공학소재연구정보센터
Fluid Phase Equilibria, Vol.332, 151-158, 2012
Experimental determination and correlation of tie line data for the system (water plus butyric acid plus methylcyclohexane) at four temperatures
This study demonstrates the experimental solubility and tie line data for (water + butyric acid + methylcyclohexane) system at temperatures of 298.2, 308.2, 318.2, and 328.2 K and atmospheric pressure. The cloud-point titration method was used to determine solubility data (binodal curves). The tie line data were determined by acidimetric titration. the Karl-Fischer technique, and refractive index measurements. The investigated ternary system exhibits type-1 behavior of liquid-liquid equilibrium. The thermodynamic models UNIQUAC and NRTL were used to correlate the experimental tie-line data. The consistency of the tie-line data was determined through the Othmer Tobias and Hand correlation equations. Distribution coefficients and separation factors were calculated over the immiscibility regions. A comparison of the extracting capability of the solvent at different temperatures was made with respect to separation factors. The Katritzky multiparameter scale was applied to correlate distribution coefficients and separation factors in this ternary system. (C) 2012 Elsevier B.V. All rights reserved.