Fuel, Vol.108, 13-18, 2013
Characterization of a regenerable sorbent for high temperature elemental mercury capture from flue gas
In this work we have developed a regenerable synthetic sorbent based on manganese oxides (12% w/w) impregnated on high surface area gamma-alumina and supported as a thin layer (40 mu m) onto cordierite honeycomb monoliths (400 cpsi). Such structured sorbents are well suited for flow-through exhaust gas treatment associated with very low pressure drop. Elemental mercury capture experiments were carried out in a lab-scale quartz reactor in air at temperatures ranging from 50 to 350 degrees C, Hg concentration in the range 50-250 mu g/m(3), GHSV = 3.6 x 10(5) h(-1). A kinetic and capacity characterization of the sorbent was conducted, giving insight on the controlling mechanisms of the mercury capture process. Structured MnOx sorbent performed satisfactorily up to 300 degrees C, the performance decaying dramatically above this temperature when desorption of elemental Hg became predominant. TPD experiments after mercury uptake on the sorbent, showed that the sorbent could be completely regenerated at a temperature as low as 500 degrees C. Repeated cycles of mercury adsorption/desorption did not lead to any significant reduction of the sorbent capacity towards mercury uptake. No significant mercury oxidation in the gas phase was observed under the operating conditions used in the experiments. (C) 2011 Elsevier Ltd. All rights reserved.