화학공학소재연구정보센터
Fuel, Vol.120, 98-115, 2014
Scrubber characterization and performance using hydrocarbons at elevated pressures
Separation efficiencies for a scrubber containing only an inlet vane was investigated. In addition holdup distribution, pressure drop, separation efficiencies and droplet separation characteristics of two wire mesh pads mounted in a scrubber were investigated experimentally at 20,50 and 85 bars using N-2/Exxsol and a synthetic Natural gas mix. The liquid holdup was recorded at five locations for the two pads. A new method was developed to allow for accurate determination of flooding point in wire mesh pads. The flooding point was determined at four inlet stream liquid volume fractions at a given pressure and fluid system. In addition droplet size measurements were performed above the wire mesh pads. The results show unexpected phenomena occurring when moving to higher pressures using liquids with low surface tensions. (C) 2013 Elsevier Ltd. All rights reserved.