화학공학소재연구정보센터
International Journal of Heat and Mass Transfer, Vol.75, 710-717, 2014
Capillary flow through rectangular micropillar arrays
This work explores capillary flow through micropillar arrays with rectangular pillar arrangements. The effects of these configurations on permeability and capillary pressure are investigated for heat pipe wick applications. The permeability is described in terms of three dimensionless parameters: h/d, l/d, and S/d, where l and S are the edge-to-edge spacings in the x- and y-directions, respectively. The two analytical permeability models considered are Hale et al. (2014) [20] and the Brinkman equation using specifically the permeability derived by Tamayol and Bahrami (2009) [19]. Permeability results from numerical simulations are also presented. The surface energy minimization program called Surface Evolver is used to calculate the capillary pressure within the arrays. Mass flow rates are first derived from a combination of array permeability and capillary pressure, and then used to predict the capillary limit of heat pipes equipped with these wicks. Rectangular arrays exhibited the ability to maintain high capillary pressures even at high porosities, which increased the overall cooling capacity above square arrays. The increase was on the order of 1.5x in the absence of gravity and 5x-7x in the presence of gravity, depending on the exact hid ratio considered. (C) 2014 Elsevier Ltd. All rights reserved.