International Journal of Hydrogen Energy, Vol.35, No.3, 1474-1484, 2010
Simulation of double-stage double-effect metal hydride heat pump
This paper presents the operational characteristics of a double-stage double-effect metal hydride heat pump (DSDE-MHHP) working with LaNi(4.1)Al(0.52)Mn(0.38)/LmNi(4.91)Sn(0.15)/ Ti(0.99)Zr(0.01)V(0.43)Fe(0.09)Cr(0.05)Mn(1.5) as high/medium/low temperature alloys. The performances of the DSDE-MHHP are predicted by solving the transient, two-dimensional, conjugate heat and mass transfer characteristics between the paired metal hydride reactors of cylindrical configuration using the finite volume method (FVM). The designed operating temperatures chosen for the present analysis are S68, 361, 296, and 289 K as heat driven (T(D)), heat rejection (T(H)), heat sink (T(M)) and refrigeration (T(C)) temperatures, respectively. The variations in hydrogen concentrations, hydride equilibrium pressures, and temperatures within the hydride beds, and the heat exchange between the hydride beds with the heat transfer fluids are presented for a complete cycle. The operating cycle of a DSDE-MHHP is explained on dynamic pressure-concentration-temperature (PCT) plot. The variation of temperatures in the reactors during hydriding and dehydriding processes is compared with experimental data and a good agreement was observed between them. For given operating temperatures of 568/361/296/289 K, the average coefficient of performance (COP) and the specific cooling power (SCP) of the system are found to be 0.471 and 28.4W/kg of total hydride mass, respectively. (C) 2009 Professor T. Nejat Veziroglu. Published by Elsevier Ltd. All rights reserved.