화학공학소재연구정보센터
International Journal of Hydrogen Energy, Vol.38, No.8, 3395-3400, 2013
Effect of non-uniform parallel channel on performance of passive direct methanol fuel cell
In this paper, the effects of current collector on passive direct methanol fuel cell's (passive DMFC) performance and removing CO2 gas is studied. For this purpose, a single cell with two arrangements of current collector in anode and cathode side is considered. In first arrangement, non-uniform parallel channels with 53.76% open ratio is used in the anode side and a perforated flow field with 34.5% open ratio is applied in the cathode side. In second arrangement, uniform parallel channels with 42.28% open ratio has been used in both anode and cathode sides. At the first arrangement, a maximum power of 20 mW cm(-2) in 4 M methanol concentrations and in the second arrangement a maximum power of 17.7 mW cm(-2) in 5 M methanol concentrations has been obtained. Furthermore, it is shown that using the current collector with non-uniform parallel channels is more effective in removing CO2 gas than other parallel channels. Copyright (C) 2013, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.