International Journal of Multiphase Flow, Vol.36, No.11-12, 908-915, 2010
Wisp-like structures in vertical gas-liquid pipe flow revealed by wire mesh sensor studies
A conductance wire mesh sensor system has been employed on a vertical 67 mm diameter pipe with the up flow of air and water mixtures. The measuring system provides time and cross-sectionally resolved information about the spatial distribution of the phases. Statistical information can be extracted and used to identify flow patterns. The fully resolved data has revealed a hitherto unreported structure has been seen in churn flow which could be linked to the wisps in wispy-annular flow. (C) 2010 Elsevier Ltd. All rights reserved.