Materials Science Forum, Vol.514-516, 1483-1487, 2006
Effect of membrane pore size and membrane-solute interactions on lysozyme ultrafiltration
A model based on steric hindrance mechanisms [1] is used to determine the pore sizes of two ultrafiltration (UF) membranes. The lysozyme rejection coefficients of those membranes are predicted through the same model after modification of the pore size and solute radius by taking into account the development of electric double layers. Two asymmetric cellulose acetate membranes M1 and M2 were prepared and characterized. Membrane M1 has an hydraulic permeability of 2.1 x 10(-6) m/s/bar, a molecular weight cut-off (MWCO) of 30,000 Da and an average pore radius of 2.6 nm. Membrane M2 has an hydraulic permeability of 5.9 x 10(-6) m/s/bar, a molecular weight cut-off (MWCO) of 60,000 Da and an average pore radius of 5.3 nm. Aqueous solutions of lysozyme containing a NaCl concentration of 0.1M were ultrafiltrated through membranes M1 and M2. The predicted lysozyme rejections considering the development of electric double layers on the protein and membrane pore surfaces, are in good agreement with the experimental results.