화학공학소재연구정보센터
Applied Microbiology and Biotechnology, Vol.98, No.20, 8719-8728, 2014
Physical lysis only (PLO) methods suitable as rapid sample pretreatment for qPCR assay
Quantitative PCR (qPCR) enables rapid and sensitive gene quantification and is widely used in genomics, such as biological, medical, environmental, and food sciences. However, sample pretreatment requires the use of conventional DNA extraction kits which are time-consuming and labor intensive. In this study, we investigated four physical lysis only (PLO) methods which are rapid and could serve as alternatives to conventional DNA extraction kits. These PLO methods are bead mill, heating, sonication, and freeze-thaw. Using ethidium bromide-based assay, their performance was evaluated and compared. The effects of cell debris and its removal were also investigated. Bead mill method without cell debris removal appeared to yield the best qPCR results among the four PLO methods. In addition, bead mill method also performed better than conventional DNA extraction kits. It is probably due to the substantial loss of DNA material during the extensive purification of the conventional DNA extraction kits. The bead mill method has been demonstrated to successfully quantify 10(2) to 10(7) copies of the PAH-RHD alpha gene of Pseudomonas putida.