Chinese Journal of Chemical Engineering, Vol.22, No.8, 950-953, 2014
CO2 Removal from Biogas by Water Washing System
CO2 removal from biogas by water washing system was investigated with various parameters, including liquid/gas ratio, pressure, temperature, and CO2 content. The results indicate that CO2 removal ratio could reach 34.6%-94.2% as liquid/gas ratio increased from 0.14 to 0.50. Increasing pressure (from 0.8 to 1.2 MPa) could improve gas purification with a constant inflow rate of gas. Temperature played a key role in the process and lower temperature in absorption tower was beneficial for reducing CO2 content. CO2 removal ratio could reach 24.4%-83.2% when CO2 content in the simulated gas was 25%-45%. The lowest CO2 content after absorption was 2.6% at 1.2 MPa with 400 L.h(-1) gas flow and 200 L.h(-1) water flow, which meets the requirement of CO2 content in natural gas for vehicle fuel. (C) 2014 The Chemical Industry and Engineering Society of China, and Chemical Industry Press. All rights reserved.