Energy, Vol.72, 590-598, 2014
Chemisorption cooling and electric power cogeneration system driven by low grade heat
A novel integration of chemisorption refrigeration cycle and a scroll expander was investigated for the cogeneration of cooling and electric power. The first lab prototype machine has been built, and the two main components were tested both independently and cooperatively for comparison before and after the integration therefore leading to better knowledge of the interaction between them. Two sets of adsorption cycles utilizing the adsorbent compound of calcium chloride and activated carbon worked out-of-phase for the output continuity, and mass recovery was applied to further elevate the performance. In the cogeneration test, the cooling temperature reached 5.4 degrees C as minimum, while the generated electric power achieved the maximum value of 490 W. The valuable experience and the inspiration on system optimization has been reaped and discussed through this exploration. (C) 2014 The Authors. Published by Elsevier Ltd.