Energy and Buildings, Vol.84, 241-251, 2014
Hygrothermal performance of exterior walls covered with aerogel-based insulating rendering
In this study, we present a recently patented insulating rendering based on silica-aerogels. It is mainly developed for exterior thermal insulation applications. In addition to new buildings, it can be used for retrofitting existing ones since it has a high insulation performance and its application is easy, compatible with the traditional masonry facades, and using the well-known ordinary techniques. The objectives are to examine the hygrothermal performance of walls with this rendering and to compare different thermal insulation configurations. The methodology followed is developing a numerical model, then conducting an experimental set-up on a test-cell having the rendering on its south wall to validate the numerical model under real weather conditions. Different exterior wall structures are examined: no insulation, exterior insulation using this rendering, interior insulation, and interior and exterior insulation. Six assessment criteria are used: assembly water content, drying rate, mold growth, condensation risk, ASHRAE-160 criterion, and heat losses. Results show that interior thermal insulation systems can cause several moisture problems: inability to dry out over the years, condensation risk, etc. Adding the aerogel-based rendering on the exterior surface of the un-insulated or the already internally insulated walls reduces significantly or even removes the moisture risks. Also, it reduces significantly the wall heat losses. (C) 2014 Elsevier B.V. All rights reserved.
Keywords:Hygrothermal wall assessment;Aerogel-based insulating rendering;WUFI numerical simulation;Experimental set-up