Energy Conversion and Management, Vol.92, 194-206, 2015
Optical losses due to tracking error estimation for a low concentrating solar collector
The determination of the accuracy of a solar tracker used in domestic hot water solar collectors is not yet standardized. However, while using optical concentration devices, it is important to use a solar tracker with adequate precision with regard to the specific optical concentration factor. Otherwise, the concentrator would sustain high optical losses due to the inadequate focusing of the solar radiation onto its receiver, despite having a good quality. This study is focused on the estimation of long-term optical losses due to the tracking error of a low-temperature collector using low-concentration optics. For this purpose, a testing procedure for the incidence angle modifier on the tracking plane is proposed to determinate the acceptance angle of its concentrator even with different longitudinal incidence angles along the focal line plane. Then, the impact of maximum tracking error angle upon the optical efficiency has been determined. Finally, the calculation of the long-term optical error due to the tracking errors, using the design angular tracking error declared by the manufacturer, is carried out. The maximum tracking error calculated for this collector imply an optical loss of about 8.5%, which is high, but the average long-term optical loss calculated for one year was about 1%, which is reasonable for such collectors used for domestic hot water. (C) 2014 Elsevier Ltd. All rights reserved.