Journal of Loss Prevention in The Process Industries, Vol.31, 127-132, 2014
The dynamic response of pressure relief valves in vapor or gas service. Part II: Experimental investigation
An experimental testing program designed to evaluate the opening stability characteristics of direct acting pressure relief valves (PRV) in gas/vapor service is described. Three different valve sizes from each of three different manufacturers were tested at two different set pressures to determine their opening characteristics (disk lift vs. time). The valves were tested with several different lengths of inlet piping as well as with and without discharge piping to determine the conditions under which unstable operation (chatter) would occur. Part I of this program described a mathematical model for predicting the dynamic response of PRV's, and the data described in this test program were used to evaluate the accuracy of the model, as described in Part III of this study to follow. (C) 2014 Elsevier Ltd. All rights reserved.