화학공학소재연구정보센터
Journal of Power Sources, Vol.274, 1049-1054, 2015
Performance evaluation of a liquid tin anode solid oxide fuel cell operating under hydrogen, argon and coal
A liquid tin anode solid oxide fuel cell is constructed and investigated under different operating conditions. Electrochemical Impedance Spectroscopy (EIS) is used to reflect the effect of fuel feed as the EIS spectra changes significantly on switching the fuel from argon to hydrogen. A cathode symmetric cell is used to separate the impedance from the two electrodes, and the results indicate that a major contribution to the charge-transfer and mass-transfer impedance arises from the anode. The OCP of 0.841 V for the cell operating under argon as a metal-air battery indicates the formation of a SnO2 layer at the electrolyte/anode interface. The increase in the OCP to 1.1 V for the hydrogen fueled cell shows that H-2 reduces the SnO2 film effectively. The effective diffusion coefficients are calculated using the Warburg element in the equivalent circuit model for the experimental EIS data, and the values of 1.9 10(-3) cm(2) s(-1) at 700 degrees C, 2.3 10(-3) cm(2) s(-1) at 800 degrees C and 3.5 10(-3) cm(2) s(-1) at 900 degrees C indicate the system was influenced by diffusion of hydrogen in the system. Further, the performance degradation over time is attributed to the irreversible conversion of Sn to SnO2 resulting from galvanic polarization. (C) 2014 Elsevier B.V. All rights reserved.