화학공학소재연구정보센터
Journal of Loss Prevention in The Process Industries, Vol.7, No.6, 451-456, 1994
MITIGATION OF HYDROGEN-FLUORIDE AEROSOLS BY DRY POWDERS
Fluid bed tests were used to determine overall reaction rates for eight different dry powders of low hazard and toxicity before and after reaction with HF. In flow chamber tests, a representative oxide, hydroxide and carbonate were used to measure the efficiency of mitigation of an HF aerosol cloud. The results show that dry powders provide a valid alternative to water spray mitigation. Powder efficiencies are higher than water efficiencies at constant weight ratio. At present, no attempt has been made to provide any technical designs or layouts for powder mitigation systems. However, the technology for smaller systems is available through manufacturers of dry powder chemical fire extinguisher equipment. When these powders are kept dry and under nitrogen atmosphere, a shelf life of several years can be expected.