Chemical Engineering Research & Design, Vol.94, 501-507, 2015
Fluidized countercurrent solvent extraction of oil pollutants from contaminated soil. Part 1: Fluid mechanics
Liquid-solid countercurrent solvent extraction is a potential application way for the removal of oil pollutant from contaminated soil. This study focuses primarily on the fluidization performance of liquid-solid two-phase flow in an extraction column (2.1 m x 50 mm diameter), with the solvent and solid flow rates ranging from 10 to 800 L h(-1) and from 8 to 107 kg h(-1), respectively. Several key hydrodynamic parameters, including pressure drop, solid holdup, superficial velocity of the solvent and solid, and dimensionless slip velocity, were investigated experimentally. At a given solid flow rate, a uniform axial distribution of solid holdup was observed at low solvent flow rate, whereas the axial solid holdup gradient increased with the solvent flow rate. The appearance of a solid holdup gradient was mainly attributed to the presence of small particles. An operating curve for the soil remediation by countercurrent solvent extraction was obtained according to the critical flow rate of the solvent and solid for predicting the occurrence of flooding and the appearance of the solid holdup gradient. (C) 2014 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.