화학공학소재연구정보센터
Chinese Journal of Chemical Engineering, Vol.23, No.3, 572-577, 2015
Performance analysis of a zeotropic mixture ( R290/CO2) for trans-critical power cycle
Low critical temperature limits the application of CO2 trans-critical power cycle. The binary mixture of R290/CO2 has higher critical temperature. Using mixture fluid may solve the problem that subcritical CO2 is hardly condensed by conventional cooling water. In this article, theoretical analysis is executed to study the performance of the zeotropic mixture for trans-critical power cycle using low-grade liquid heat source with temperature of 200 degrees C. The results indicated that the problem that CO2 can't be condensed in power cycle by conventional cooling water can be solved by mixing R290 to CO2. Variation trend of outlet temperature of thermal oil in supercritical heater with heating pressure is determined by the composition of the mixture fluid. Gliding temperature causes the maximum outlet temperature of cooling water with the increase of mass fraction of R290. There are the maximum values for cycle thermal efficiency and net power output with the increase of supercritical heating pressure. (C) 2015 The Chemical Industry and Engineering Society of China, and Chemical Industry Press. All rights reserved.