화학공학소재연구정보센터
Applied Chemistry, Vol.2, No.1, 254-257, May, 1998
모델도금폐수로부터 막분리를 이용한 중금속이온 제거
Rejection of Heavy Metal Ion by Using Membrane Separation from Model Plating Wastewater
At 1.00, 1.17, 1.40, 1.75 and 2.33 of VCR of model wastewater 100mg/L, concentration and condutivity of heavy metal ion in the concentrated solution and permeate water was measured by using ion Chromatography and Conductivity Meter. For example, concentration of Ni2+ ion increased from 100mg/L to 180.9mg/L and permeate water was from 8.3mg/L to 9.4mg/L and rejection ratio was from 91.7% to 93.2 %. Conductivity of concentrated water was from 102.l㎲/cm to 271.0㎲/cm and permeate water was from 10.1㎲/cm to 10.88㎲/cm and rejection ratio was from 90.1% to 93.8%.