화학공학소재연구정보센터
Journal of Adhesion Science and Technology, Vol.29, No.23, 2515-2520, 2015
Uncertainty in contact angle estimates from a Wilhelmy tensiometer
The uncertainty in contact angles from the Wilhelmy tensiometer was analyzed using standard error propagation techniques involving partial derivatives across the full range of wettability, from completely wetting to non-wetting surfaces. Uncertainties in force, sample perimeter, and liquid surface tension of 1% were shown to yield uncertainty in contact angles of a few degrees over the middle range of wettability, but exceeded 10 degrees at the extremes.