Copper Iron Conversion Coating for Solid Oxide Fuel Cell Interconnects
A conversion coating of iron and copper was investigated with the purpose of increasing the performance of Sanergy HT as a potential SOFC interconnect material. Samples were exposed to a simulated cathode atmosphere (air, 3 % H2O) for durations of up to 1000 h at 850 degrees C. Their performance in terms of corrosion, chromium evaporation and electrical resistance (ASR) was monitored and compared to uncoated and cobalt-coated Sanergy HT samples. The copper iron coating had no negative effects on corrosion protection and decreased chromium evaporation by about 80%. An Area Specific Resistance (ASR) of 10 m Omega cm(2) was reached after 1000 h of exposure. Scanning Electron Microscopy revealed well adherent oxide layers comprised of an inner chromia layer and an outer spinel oxide layer. (C) 2015 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license