Powder Technology, Vol.277, 22-35, 2015
Investigation on dust collection and particle classification performance of cyclones by airflow control for design of cyclones
We investigated the design of relatively large cyclones with large amounts of airflow containing dust that are used in actual dust collection plants. In order to obtain basic data on the design of conical cyclones with a Reynolds number of approximately 8.9 x 10(5), we compared the fluid analysis results with the experimental results on dust collection and particle classification performance for conical cyclones to which apex cones and stabilizers were attached. Then, we elucidated the relationship between the flow conditions inside the conical cyclone with a Reynolds number of 8.9 x 10(5) and dust collection and particle classification performance. (C) 2015 Elsevier B.V. All rights reserved.