화학공학소재연구정보센터
Chemical Engineering Science, Vol.143, 314-340, 2016
CFD simulations of shell-side flow in a shell-and-tube type heat exchanger with and without baffles
Shell-and-tube heat exchanger has been extensively used in industrial and research fronts for more than a century. However, most of its design procedures are based on empirical correlations extracted from experimental data of long length shell and tube heat exchanger. In this paper, an attempt has been made to investigate the complex flow and temperature pattern in such a short shell and tube type heat exchanger, with and without baffles in the shell side. Heat exchangers of length by hydraulic diameter ratio between 7 < L/D-h < 21(0.15 m