Fuel, Vol.177, 87-106, 2016
Comparison of evaporation rate and heat flow models for prediction of Liquefied Natural Gas (LNG) ageing during ship transportation
The prediction of ageing phenomena in Liquefied Natural Gas is based on two hypotheses: considering evaporation rate or considering heat flow transferred to the hydrocarbons mixture. This paper proposes two models based on these premises and validates them against other numerical models described in the scientific literature. Then, the results of the two ageing approaches are compared with a database containing experimental measurements at the loading and unloading ports for 558 voyages by a number of different LNG carriers. The weathering models based on evaporation rate are more accurate than ageing models based on heat flow for the following variables at the discharge port: Methane content, Higher Heating Value, Wobbe Index, Liquid Density, LNG volume and temperature. The effects of ship capacity and voyage duration on accuracy are also described. Finally, the evolution over time of the aforementioned variables is reported for a specific voyage. (C) 2016 Elsevier Ltd. All rights reserved.
Keywords:Liquefied Natural Gas ageing;Weathering;Boil-off rate;LNG carrier;Constant heat flow;Evaporation rate