화학공학소재연구정보센터
Journal of Petroleum Technology, Vol.47, No.2, 127-128, 1995
Field-Measurements of Casing Tension Forces
Tension forces acting on individual casing joints were accurately measured during installation of 10, 158 ft of 9(5)/8-in. x 47-lbm/ft csing and 11,960 ft of 11(7)/8-in. x 71.8-lbm/ft casing. A unique casing load table (CLT) weighed the casing string after the addition of each casing joint. Strain gauges attached inside the pin ends of instrumented casing joints (ICJ’s) directly measured tension force on those joints. A high-speed computer data-acquisition system (DAS) automatically recorded data from all the sensors. Several casing joints were intentionally subjected to extreme decleration to determine upper limits for dynamic tension forces. Data from these tests clearly show effects of wellbore friction and casing handling conditions. In every case, tension forces in the casing during maximum deceleration were considerably less than expected. In some cases, the highest tension forces occurred when the casing lifted out of the slips. Peak tension forces caused by setting the casing slips were typically no more than 5% greater than tension forces in the casing at rest. This dynamic amplification was far less than the 60% value used in the previous casing design method. Reducing the safety factor for installation loads has permitted use of lighter, less-expensive casing than dictated by older design criteria.