화학공학소재연구정보센터
Materials Chemistry and Physics, Vol.181, 67-77, 2016
Corrosion behavior of plasma electrolytically oxidized gamma titanium aluminide alloy in simulated body fluid
Plasma electrolytic oxidized (PEO) gamma TiAl alloy samples were electrochemically characterized by open circuit potential (OCP), cyclic polarization and electrochemical impedance spectroscopy (EIS) to evaluate their corrosion resistance in simulated body fluid (SBF) in order to gauge their potential for biomedical applications. Experimental results through OCP and cyclic polarization studies demonstrated the protective nature and the beneficial effect of the PEO coatings on gamma TiAl. The PEO surface increased corrosion resistance of these surface modified alloys. EIS data indicated the presence of an underlying compact oxide layer with surface pores represented by two domes in the Nyquist plots. Electrical equivalent circuits to describe the EIS results are proposed. (C) 2016 Elsevier B.V. All rights reserved.