Process Safety and Environmental Protection, Vol.102, 251-262, 2016
Runaway decomposition of dicumyl peroxide by open cell adiabatic testing at different initial conditions
Low-thermal inertia experiments in the open cell configuration were carried out to perform a comprehensive sensitivity analysis of the parameters affecting the runaway self decomposition of dicumyl peroxide (DCP). This study facilitates a better understanding on how concentration, initial back pressure, and fill level influence DCP runaway severity The outcome of this experimental study was compared to previous adiabatic closed cell experiments, with the aim of clarifying the discrepancies reported in the literature and contributing to essential knowledge about self-decomposing peroxide systems. Results showed that the detected onset temperature, maximum temperature, maximum pressure, and time to maximum rate are affected by the configuration of the equipment and initial back pressure of the experiments, while the adiabatic temperature rise did not seem to be affected. The roles that the kinetics, fluid dynamics, and thermodynamics play on these observations is addressed and discussed through the manuscript. (C) 2016 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
Keywords:Thermal decomposition;Dicumyl peroxide;Open cell adiabatic calorimetry;Experimental sensitivity analysis;Hazard identification;Process design