화학공학소재연구정보센터
Industrial & Engineering Chemistry Research, Vol.56, No.31, 8797-8805, 2017
Benzothiazole-Based Fluorescent Sensor for Ratiometric Detection of Zn(II) Ions and Secondary Sensing PPi and Its Applications for Biological Imaging and PPase Catalysis Assays
In this paper, we designed and synthesized three benzothiazole-based fluorescent probes L-1, L-2, and L-3 for zinc ion detection. Among various metal ions, only the zinc ion exhibited fluorescence enhancement at 475 nm accompanied by the blue-shift emission wavelength in HEPES buffet solution containing probes. Through titration experiment, the detection limit of L-1 for zinc ion sensing was calculated to be as low as 7 nM, which showed a high sensitivity. Furthermore, the confocal laser scanning micrographs,of HeLa cells demonstrate good cell permeability of probe L-1 and selective detection of zinc ion in living cells. The L-1-Zn2+ complex was further used for pyrophosphate (PPi) sensing in HEPES buffer solution, the limit of detection was calculated to be as low as 60 nM. L-1-Zn2+ can monitor the enzyme catalyzed degradation process of PPi, thus providing a Meaningful way for tracking of zinc ion and pyrophosphate in biological systems.