Journal of the Electrochemical Society, Vol.164, No.13, F1342-F1347, 2017
Electrochemical Validation of In-Cell Chromium Getters to Mitigate Chromium Poisoning in SOFC Stack
A porous, electrically conductive getter layer, consisting of mixtures of metal oxide getter and an electrically conducting perovskite phase, has been fabricated for incorporation in between the cell interconnect and the cathode to capture gaseous chromium species. Getter layer has been electrochemically tested in half-cell configuration in the presence of chromium vapor (Cr2O3 /Air-3% H2O) at 850 degrees C for 100 hours. The electrochemical performance remains stable as evidenced by stable current density (I-t) at 0.5 V applied bias and EIS data obtained during the test. Tested cells were analyzed for the composition of reaction products and changes in the morphology. The gaseous chromium predominantly concentrated at the impinging getter surface, and the bulk electrode and electrode-electrolyte interface remained free of chromium. (c) 2017 The Electrochemical Society. All rights reserved.