화학공학소재연구정보센터
Materials Chemistry and Physics, Vol.210, 37-42, 2018
Mechanical performance of FeCrCoMnAlx high-entropy alloys from first-principle
The elastic parameters and ideal tensile strength in the 10011 direction for the body-centered cubic solid solution phase of FeCrCoMnAlx (0.6 <= x <= 1.5) high-entropy alloys are determined using first-principle alloy theory. Based on the estimated theoretical Curie temperatures, all alloys considered here are predicted to order ferromagnetically at room temperature. The mechanical behaviors are analyzed through the single-crystal and polycrystalline elastic moduli, Pugh ratio, and Debye temperature by making use of a series of phenomenological models. High ideal tensile strength is found for the equiatomic FeCrCoMnAl system, and the intrinsic strength increases with decreasing Al content. (C) 2017 Elsevier B.V. All rights reserved.