Journal of Power Sources, Vol.78, No.1-2, 199-203, 1999
Development and testing of a bipolar lead-acid battery for hybrid electric vehicles
An 80 V bipolar lead-acid battery was constructed and tested using hybrid electric vehicle (HEV) drive cycles. Drive cycles with a peak power of 6.7 kW, equal to 1/5 of the total power profile required for the HEV studied, were run successfully. Model calculations showed that the 80 V module constructed, which is at the moment 2.5 times heavier than required for the HEV operation studied, can be optimised to meet the requirements.
Keywords:EBONEX(R) ELECTRODES;LEAD/ACID BATTERIES