화학공학소재연구정보센터
Journal of the Electrochemical Society, Vol.165, No.9, F710-F717, 2018
Strategies for Reducing the PGM Loading in High Power AEMFC Anodes
Anion Exchange Membrane Fuel Cells (AEMFCs) have experienced a significant rise in attention in recent years, largely motivated by the potential to overcome the costs that have plateaued for proton exchange membrane fuel cells. However, despite significant advances in power generation, membrane conductivity, membrane stability, and catalyst activity, the vast majority of high performing AEMFCs are fabricated with a high PGM loading (0.4-0.8 mg cm(-2)). This work demonstrates an electrode fabrication method that reduces the anode catalyst loading by 85% while still achieving performance ca. 1 W cm(-2) - accomplished by designing a multilayered electrode comprised of an optimized ionomer:carbon:PGM ratio catalyst layer coupled with a hydrophobic microporous layer. If paired with a high-performing PGM-free cathode, this new anode shows the potential to meet existing DOE PGM loading and performance targets. (C) The Author(s) 2018. Published by ECS.