화학공학소재연구정보센터
Transport in Porous Media, Vol.127, No.2, 371-389, 2019
Quantitative In-situ Analysis of Water Transport in Concrete Completed Using X-ray Computed Tomography
This paper describes a novel methodology for quantitative in-situ moisture measurement without tracking agents using X-ray computed tomography (XCT). The high levels of greyscale precision required for the measurement of moisture without tracking agents resulted in the need for an additional image calibration procedure to correct for water-related X-ray scattering and for equipment-variability-related artefacts arising during in-situ testing. This calibration procedure was developed on the basis of existing principles of XCT image correction. Resulting images of moisture distribution exhibit a high level of agreement with expected material behaviour. This research demonstrated that XCT can be successfully used to measure both moisture front movement over time and changes in 3D moisture distribution within samples. This approach to moisture measurement lays the groundwork for the planned future investigation of the interaction between cracking induced by varying chemical and mechanical processes and water transport in concrete.