Industrial & Engineering Chemistry Research, Vol.58, No.22, 9651-9664, 2019
Cross Sectional Examination of a Fouled Tube Removed from a Crude Oil Preheat Exchanger
A first attempt to characterize intact foulant of a refinery preheater is presented. A tube was removed from an exchanger located postdesalter and preflash-drum at a 4-year shutdown, and dissected into undisturbed cut-out rings. Following visual inspection, elemental analysis (X-ray maps and line scans) was carried out and radial concentration profiles of the existing elements were established. A stratified colored foulant layer inside the tube appeared in sine waves fluctuating at both axial and angular directions, likely evidencing for the first time a shadow effect and erosion process. Results agreed with our studies on a comparable exchanger of the same refinery. They confirm the proposed deposition mechanism and simulation results, indicating formation of a stratified foulant consisting inorganics ranging 50 wt %, the presence of an acute inorganic deposition period along the chronic organic-inorganic fouling, and the identification of the foulant phases arrangement, among possible conductivity mixing models, as cocontinuous and effective medium theory structures.