화학공학소재연구정보센터
Journal of Chemical Technology and Biotechnology, Vol.95, No.3, 806-812, 2020
Passive micromixer with baffles distributed on both sides of microchannels based on the Koch fractal principle
Since the beginning of the 21st Century, the development of microfluidic chip technology has been very rapid and has attracted the attention of more and more scholars. As an important part of the microfluidic chip, the performance of the micromixer is critical. The fractal structure in the microchannels helps to improve the mixing performance of the micromixer and improve the mixing efficiency of the micromixer. The research results of other scholars are of great significance to the research of the present paper, which mainly studies the effect of changing the baffle state on the mixing efficiency of the micromixer based on the Koch fractal principle. Through simulation analysis, it was found that the mixing efficiency of the baffles distributed on both sides of the microchannel was higher than the mixing efficiency of the baffles distributed on the microchannel side. When the distance between adjacent baffles was divided into 0.15, 0.25 and 0.35 mm, simulated data suggested that the baffle distance of 0.15 mm was best. Increasing the number of baffles from six to eight groups increased the mixing path of the fluid in the microchannel and improved mixing efficiency. A comparison of mixing efficiencies of the 0 degrees, 15 degrees and 30 degrees baffle angles revealed that very significant improvement in mixing efficiency was obtained at 30 degrees. (c) 2019 Society of Chemical Industry