화학공학소재연구정보센터
International Journal of Energy Research, Vol.44, No.3, 1506-1518, 2020
Performance investigation in modified and improved augmented power generation Kalina cycle using Python
In the generation of electricity and cogeneration, Kalina cycle is considered as one of the competitors to organic Rankine cycle. With the simplicity and identical components of the binary mixture, Kalina system makes it more prominent to get developed and implemented as well with its environmental friendly associate. This work proposes a new improved Kalina cycle system to convert the natural source from sun to useful work. The proposed system utilizes heat source suitable to medium temperature heat applications. The proposed cycle have 2 units of solar collector, favoring an additional heat recovery and higher performance. Solar hot source temperature and pressure are 190 degrees C and 45 bar with additional flow to the turbine of 1.15 kg/s. Energy and second law analysis have considered in evaluating the performance of the proposed plant. The energy analysis shows minimum value of net power, energy efficiency and plant efficiency as 241 kW, 15.5% and 5.7. The exergy analysis defines that, to the proposed cycle, the exergy efficiency initializes at 77% with more exergy destruction at turbine with 31%. With the parametric analysis, the system is amended to have the maximum values of energy and exergy performances as 18.5%, 7.1% and 85%. The parametric study identifies the optimum value of the inlet temperature and pressure of the pump and turbine.