Solid State Ionics, Vol.109, No.3-4, 279-284, 1998
Time-domain electrical responses of sodium diborate glass
In the study of ionic conduction in an ionic conductor, the d.c. technique has usually been avoided in the belief that the accompanying 'electrode polarization' would deteriorate data analysis. The aim of the present work was to re-evaluate the d.c. technique using a single-shot purse of various duration.