Chinese Journal of Chemical Engineering, Vol.9, No.2, 141-144, 2001
Operation of a batch stripping distillation column
A stripping batch distillation column is preferred when the amount of the light component in the feed is small and the products are to be recovered at high purity. The operation modes of a batch stripping are believed to be the same as those of a rectifier. However, the control system of a stripper is different. In this paper, we explore three different control methods with Hysys (Hyprotech Ltd. 1997) for a batch stripper. The main difference is the control scheme for reboiler liquid level: (a) controlled by reflux flow; (b) controlled by reboiler heat duty; (c) controlled by bottom product flow. The main characteristics of operating a batch stripper with different control scheme are presented in this paper. Guidelines are provided for the startup of a batch stripper, the effects of some control tuning parameters on the column performance are discussed.